論文

基本情報

氏名 高山 弘幹
氏名(カナ) タカヤマ ヒロキ
氏名(英語) Hiroki TAKAYAMA
所属 【教員用】 通学課程 保医技学部 理学療法学科
職名 助教
researchmap研究者コード R000039570
researchmap機関 佛教大学

題名

Reliability of a Measurement Method for Upper Limb Raised Standing Spinal Alignment Using a Smartphone Inclinometer Application

単著・共著の別

著者

Hiroki Takayama
Koji Miyawaki
Masatoshi Nakamura

担当区分

概要

Abstract

Purpose: To evaluate the reliability and validity of spinal alignment measurements in the raised arm standing posture using a smartphone app.
Background: An inclinometer is a reliable tool for measuring spinal alignment. Measurement of static standing posture spinal curvature angles using smartphone inclinometer applications has been investigated in the lumbar spine but has not been reported for the thoracic spine. However, the sacral vertebrae were used as the reference point for the measurement of the lumbar spine, and the method of palpation of the sacral vertebrae was unclear. No measurement methods, including inclinometers, have been found for upper limb elevation.
Methods: Thoracic kyphosis and lumbar lordosis angles were measured in 18 healthy young adults (mean age: 21.0 ± 3.5). Measurements were taken in the raised standing posture. The points of measurement included angle α at the thoracic spine (T)1/2, angle β at the T12/lumbar spine (L)1, and angle γ at the L4/L5 spinous processes. The thoracic kyphosis angle was calculated as the sum of α and β, while the lumbar lordosis angle was the sum of β and γ. Two raters measured these angles twice using the same smartphones. Inter-rater reliability was assessed using intraclass correlation coefficients (ICC 2.1), and measurement precision was determined by calculating MDC95 from the ICC values. Validity was also carried out on 12 healthy young adults (age: 20.8 ± 4.0 years). The measurement points were the same as described above, and two types of measurements were taken with a smartphone and an inclinometer; the results of the two types of measurements were used to determine the relationship using Pearson's correlation coefficient.
Results: During upper limb raising, the smartphone's ICC (95% confidence interval) was 0.92 (0.81-0.97) for thoracic kyphosis and 0.90 (0.74-0.96) for lumbar lordosis. The MDC95 values indicated acceptable precision, with 7.00° for thoracic kyphosis and 9.95° for lumbar lordosis. All correlation coefficients between inclinometers and smartphones were above 0.9 for both the thoracic and lumbar spines.
Conclusions: Measuring spinal alignment angles using a smartphone inclinometer app in the raised standing posture demonstrates good reliability for inter-rater comparisons. It was also good with regard to validity.
Keywords: inclinometer; lumbar lordosis; overhead position; smartphone; thoracic kyphosis.

発表雑誌等の名称

Cureus

出版者

Springer Science and Business Media LLC

巻

16

号

12

開始ページ

終了ページ

発行又は発表の年月

2024/12/22

査読の有無

有り

招待の有無

記述言語

掲載種別

研究論文(学術雑誌)

国際・国内誌

国際誌

国際共著

ISSN

eISSN

ISBN

DOI

10.7759/cureus.76225

Cinii Articles ID

Cinii Books ID

Pubmed ID

39845224

PubMed Central 記事ID

形式

無償でアクセス可能

JGlobalID

arXiv ID

公開開始(予定)日

DOIランディング先

関連情報URL

ORCIDのPut Code

DBLP ID

論文の学内分類

主要業績フラグ

その他